System 3000 AIR TERMINALS

Part Number Weight Part Number Installation Height
D/SMKIVSS 2.6 kg INTMKIVSS 20 m Max

System 3000 FRP Masts

Part Number L T OD
FRP2MBLACK 2.0 m 4 mm 68 mm
FRP4.6MBLACK 4.6 m 4 mm 68 mm

System 3000 Aluminium Masts (Aluminum)

Part Number L T OD
ALUM3M 3 m 4 mm 69.9 mm
ALUM4M 4 m 4 mm 69.9 mm
ALUM5M 5 m 4 mm 69.9 mm
ALUM6M 6 m 4 mm 69.9 mm

System 3000 Aluminium Mast with Base (Aluminum)

Part Number H Plate Size Ø
MBMAST3M 3 m 229 x 229mm 69.9 mm
MBMAST4M 4 m 229 x 229mm 69.9 mm
MBMAST5M 5 m 229 x 229mm 69.9 mm
MBMAST6M 6 m 229 x 229mm 69.9 mm

System 3000 Mast Coupling (Aluminum)

Part Number H L W
ILCOUPL 113 mm 475 mm 137 mm

System 3000 Mast Bracket (Aluminium)

Part Number Ø TL W X H
UBOLT 78.5mm 89mm 128 x 51mm

System 3000 Mast Bracket (Stainless Steel)

Part Number OD HS A
70000250S4 76.1 mm 11mm 304.8 mm

System 3000 Guy Kits (Fibreglass, Polyvinylchloride)

Part Number Mast Height Weight
GUYKIT4M/GRIP 4 m 0.4kg
GUYKIT7M/GRIP 7 m 0.7kg
GUYKIT10M/GRIP 10 m 1.0kg
GUYKIT12M/GRIP 12 m 1.2kg
GUYKIT17M/GRIP 17 m 1.7kg

Guy Ring (Aluminium)

Part Number Weight
GUYRING 0.118kg

System 3000 Downconductor (ERICORE Insulated Cable)

Part Number L Specs CSA
ERICORE 1 m 0.75 nF, 37nH, 0.5mΩ/m (Rdc), 6mΩ/m (Rimp) 50 mm²
ERICORE/CUT/SHORT 1 – 25 m 0.75 nF, 37nH, 0.5mΩ/m (Rdc), 6mΩ/m (Rimp) 50 mm²
ERICORE/CUT/MEDIUM 26 – 90 m 0.75 nF, 37nH, 0.5mΩ/m (Rdc), 6mΩ/m (Rimp) 50 mm²
ERICORE/CUT/LONG 91 – 200 m 0.75 nF, 37nH, 0.5mΩ/m (Rdc), 6mΩ/m (Rimp) 50 mm²
ERICORE/CUT/XLONG 201 – 250 m 0.75 nF, 37nH, 0.5mΩ/m (Rdc), 6mΩ/m (Rimp) 50 mm²

ERICORE Termination (Upper Terminations (Factory Fitted))

Part Number Termination Location
ERICORE/TERM/IN/SHORT Inside Drum
ERICORE/TERM/OUT/SHORT Outside Drum

ERICORE Termination (Lower Termination)

Part Number
ERICORE/LTKIT/A

System 3000 Downconductor Saddles (ERICORE Conductor Saddle)

Part Number W D HS
CONSADE25 114.5mm 25.5mm 6mm

Lightning Event Counters (Electronic)

Part Number Trip Threshold D H
LECV 1 kA 8/20 μs – 100 kA 10/350 μs 42 mm 141 mm

Lightning Event Counters (Mechanical)

Part Number Trip Threshold D H
LECIV 2 kA 8/20 μs 65 mm 110 mm

Lightning Event Counters (Remote Monitored)

Part Number Trip Threshold D H
LECIVR 2 kA 8/20 μs 65 mm 110 mm
Comes with 25m Fibre Optic Lead to Din-rail Mounted Monitoring device, with relay closure output.